Diagnostic error codes, Sc ii front panel leds, Back of site controller ii – Gasboy CFN Series CFN II Quick Reference User Manual

Page 23: Disk drive, Dip switch bank 1, Test points, Top row: boot & device, Bottom row: pcmcia board

background image

CFN II Quick Reference

C09159 Rev. 2238

19

DIP Switch Bank 1

Position & Definition

Setting(*=customary)

1 enable

battery

1

*on=enabled
off=disabled

2

enable battery 2

on=enabled
*off=disabled

3

battery backup for SC I
CPU RAM

*off=disabled
on=enabled

4

on=SC I; off=SC II

*off

Test Points

Test Point

Function

Voltage

TP1

battery 1

3.0 - 3.5 VDC

TP2

battery 2

3.0 - 3.5 VDC

TP3 ground

0

VDC

TP4

vcc

4.90 - 5.10 VDC

SC II Front Panel LEDs

Top Row: Boot & Device

o o o o o o o o o o o o
L1 L12

LED During Initialization

After Initialization

L1

____

Transmit data on 422 loop #2

L2

____

Receive data on 422 loop #2

L3

____

Transmit data on 422 loop #1

L4

____

Receive data on 422 loop #1

L5

Reached monitor mainline AC power fail, also host poll

L6

Monitor variables initial-
ized

CFN host poll

L7

Host port initialized

FPR poll

L8

Console port initialized

Reader poll

L9

Monitor RAM cleared

Pump control unit poll

L10

Vectors copied to RAM

Console poll

L11

CIO initialized

Blinks once per second

L12

Reached EPROM

Check sum complete

Bottom Row: Old Memory Board

o o o o
LED 1 2 3 4

LED

Color

Function

LED 1

red

on when battery #1 fails

LED 2

red

on when battery #2 fails

LED 3

red

on when battery #3 fails

LED 4

green

on when battery backup voltage is
okay

Bottom Row: PCMCIA Board

o o
LED 1 2

LED

Color

Function

LED 1

green

both batteries okay

LED 2

red

one or both batteries bad

Back of Site Controller II

Port and Loop numbers.

Diagnostic Error

Codes

The following error codes may appear in response to
PRINT DIAGNOSTICS;A.

Disk Drive

These error codes are shown in the Site Controller
section of the diagnostics printout.

NB0—Drive A: not ready
NB1—Drive A: sector not found
NB2—Drive A: CRC error (cyclical redundancy

check)

NB3—Drive A: write protected
NB4—Drive B: not ready
NB5—Drive B: sector not found
NB6—Drive B: CRC error (cyclical redundancy

check)

NB7—Drive B: write protected
NB8—Drive C: not ready
NB9—Drive C: controller error
NBA—Drive C: CRC error (cyclical redundancy

check)

NBD—Drives E & F: not ready
NBE—Drive E: write protected