Diagnostic error codes, Sc ii front panel leds, Back of site controller ii – Gasboy CFN Series CFN II Quick Reference User Manual
Page 23: Disk drive, Dip switch bank 1, Test points, Top row: boot & device, Bottom row: pcmcia board

CFN II Quick Reference
C09159 Rev. 2238
19
DIP Switch Bank 1
Position & Definition
Setting(*=customary)
1 enable
battery
1
*on=enabled
off=disabled
2
enable battery 2
on=enabled
*off=disabled
3
battery backup for SC I
CPU RAM
*off=disabled
on=enabled
4
on=SC I; off=SC II
*off
Test Points
Test Point
Function
Voltage
TP1
battery 1
3.0 - 3.5 VDC
TP2
battery 2
3.0 - 3.5 VDC
TP3 ground
0
VDC
TP4
vcc
4.90 - 5.10 VDC
SC II Front Panel LEDs
Top Row: Boot & Device
o o o o o o o o o o o o
L1 L12
LED During Initialization
After Initialization
L1
____
Transmit data on 422 loop #2
L2
____
Receive data on 422 loop #2
L3
____
Transmit data on 422 loop #1
L4
____
Receive data on 422 loop #1
L5
Reached monitor mainline AC power fail, also host poll
L6
Monitor variables initial-
ized
CFN host poll
L7
Host port initialized
FPR poll
L8
Console port initialized
Reader poll
L9
Monitor RAM cleared
Pump control unit poll
L10
Vectors copied to RAM
Console poll
L11
CIO initialized
Blinks once per second
L12
Reached EPROM
Check sum complete
Bottom Row: Old Memory Board
o o o o
LED 1 2 3 4
LED
Color
Function
LED 1
red
on when battery #1 fails
LED 2
red
on when battery #2 fails
LED 3
red
on when battery #3 fails
LED 4
green
on when battery backup voltage is
okay
Bottom Row: PCMCIA Board
o o
LED 1 2
LED
Color
Function
LED 1
green
both batteries okay
LED 2
red
one or both batteries bad
Back of Site Controller II
Port and Loop numbers.
Diagnostic Error
Codes
The following error codes may appear in response to
PRINT DIAGNOSTICS;A.
Disk Drive
These error codes are shown in the Site Controller
section of the diagnostics printout.
NB0—Drive A: not ready
NB1—Drive A: sector not found
NB2—Drive A: CRC error (cyclical redundancy
check)
NB3—Drive A: write protected
NB4—Drive B: not ready
NB5—Drive B: sector not found
NB6—Drive B: CRC error (cyclical redundancy
check)
NB7—Drive B: write protected
NB8—Drive C: not ready
NB9—Drive C: controller error
NBA—Drive C: CRC error (cyclical redundancy
check)
NBD—Drives E & F: not ready
NBE—Drive E: write protected
NBF—Drive F: write protected