Wayne, Interface board – Gasboy CFN Series CFN II Quick Reference User Manual
Page 49

CFN II Quick Reference
C09159 Rev. 2238
45
Position & Definition
Setting(*=customary)
1 (see
below)
2
# of pumps per loop
*open=6 dual pumps
closed=8 dual pumps
3 dead
man
timer
*open=enabled
closed=disabled
4 (see
below)
5-8 ____
Dip Switch Bank 4 for a single-display price bar:
Pricing policy
Bar shows
level:
SW4-1
SW4-4
all levels have same
price
1
2
op
op
cl
op
level 1 same as level 2
1
2
op
op
cl
op
level 0 same as level 1
1
2
op
op
cl
op
levels 0, 1, and 2 all dif-
ferent
1
2
cl
cl
cl
op
Dip Switch Bank 4 for a cash/credit select button,
dual-display price bar, or a single alternating-display
price bar (only three prices levels—0, 1, 2—can be
loaded, and level 0 must be the same as level 1 or
level 2):
Pricing policy
SW4-1
SW4-4
level 0 same as level 1
op
cl
level 0 same as level 2
op
op
Front Panel LEDs
L1 L12
o o o o o o o o o o o o
o o o
DC BOK BAD
Lamp Indication
L1
TxD on CRIND 422 port
L2
RxD on CRIND 422 port
L3
transmit data on 422 loop #1
L4
receive data on 422 loop #1
L5
dead man timer refresh
L6
current loop power enabled
L7
current loop #1 active if flashing
L8
current loop #2 active if flashing
L9
program crash code bit 1
L10
program crash code bit 2
L11
program crash code bit 3
L12
program crash code bit 4
DC
DC 5V power OK (green)
BOK
battery OK (green)
BAD battery
bad
(red)
Interface Board
Jumper
Function and/or Normal Setting
K1
Baud rate clock source; must be installed in
position 1.
K2
Battery backup enable. Boards should be stored
with this jumper out; it should be installed at
assembly time. Lamp BAD will light if K2 is
omitted.
SC II Pump Configuration
Notes: Pump limits and card limits must be in
dollars, not volume; for a cash/credit pump ($/Cr),
the limit must be $999. Grade assignments must be
entered as hose numbers.
In the PUMP configuration program, in submenu 3,
set the following options:
Gilbarco type
Options to set
Highline (old)
6,9
Highline 9
Highline$/Cr 3,9
MPD 1,5,9
MPD $/Cr
1,3,5,9
Wayne
The cable that connects the Wayne controller with
port 1 or 3 of the Site Controller II is part number
C04654. The pins in the cable are wired like this:
With the Wayne controller, use the Wayne jumper
settings on the Site Controller II that are shown under
CPU Board in the Site Controller II section of this
pocket reference.
The Wayne controller must be set at 1200 baud.
For Wayne pumps:
•
the cash price must be lower than or equal to the
credit price.
•
the pump limit must be $999 for the cash/credit
Male DB-25P
Connector
Female DB-25S
Connector
2
2
3
3
4
4
5
5
6
6
7
7
8
8
20
20