beautypg.com

Scii cpu board, Switches, Jumpers – Gasboy CFN Series CFN II Quick Reference User Manual

Page 21

background image

CFN II Quick Reference

C09159 Rev. 2238

17

%Q

Site shift sequence number; each site shift
change increments this number.

%R Site

run

level:

0

=

running

1 = blocking new transactions

2 = stopped

3 = emergency stopped

4 = memory full

5 = crashed

%S

Current site shift number (1, 2, or 3).

%T

Time (HH:MM AM/PM).

%U

User number of user currently signed on.

%V

Site version number.

%W

Day of week-Sun, Mon, Tue, Wed, Thu, Fri,
Sat.

%Y Date-time

(YYMMDDHHMM).

%a-%z User string variables set by SET_VAR; up

to 38 characters long.

SCII CPU Board

Part number: C05328.

Switches

DIP Switch Bank 1

Position & Definition

Setting(*=customary)

1 back-up

sign-on

*open=disabled
closed=enabled

2

hard disk access

open=disabled
*closed=enabled

3-6 ____

7-8

boot mode & LEDs

*open (see below)

Note: If switch 1-2 is closed and there is no hard disk
controller, the Site Controller will crash.

1-7

1-8

Reset

LEDs

Crash

open open boot normal boot

closed open boot normal

debugger

open closed boot scan boot

closed closed

debugger scan debugger

DIP Switch Bank 2

Port and Switch number:

Baud

Rate

Local

1 2

Remote

3 4

Not Used

5 6

Log Printer

7 8

300

op op

op op

op op

op op

1200

cl op

cl op

cl op

cl op

2400

op cl

op cl

op cl

op cl

9600

cl cl

cl cl

cl cl

cl cl

If the log output is configured to go to port 0 on the
back of the Site Controller II, the log printer port
baud-rate switches are ignored and the baud rate is
the same as the local port’s rate.

Jumpers

Jumpe
r

Setting

Setting

Default

K1,K2 (see

below)

K23 Tx

clock

output

out

K24

receive clock input

out

K25

Tx clock input

out

K26

1-2=disable AC fail

2-3=enable AC fail

2-3

K27 dead

man

timer disabled=out

enabled=in

in

K28

2-3=hard reset

2-1=soft reset

2-1

K35

in=boot state cleared
after power up

out=boot state not
cleared after power up

in

RS-232 Port Jumpers—K1, K2

The following two charts show the jumper
configuration for various tasks for ports 1 and 3 of
the Site Controller II. Ports 1 and 3 are multi-purpose
for communication applications or pump interfacing.
K1 is for port 1; K2 is for port 3.

‘Old’ Tokheim settings are used if the Tokheim
pump driver is before version 2. ‘New’ indicates
version 2.0 and above (asynchronous modems).

Note: The special jumper configuration shown below
for Hayes modems may be used to eliminate spurious
“DSR Regained” messages; if this is not a problem,
then the standard modem jumper configuration may
be used.