New installation:

Connect a Tokheim Splitter to port 1 or port 3 on
the SC II.

Connect a C05578 cable (for one 67 box) or a
C05876 cable (for two 67 boxes) to the Splitter.
Connect the other end(s) of the cable to the
Tokheim box or boxes.

Check jumper and configuration settings.

Upgrading an existing installation:

If you are not installing version 2.0 of the pump
driver, connect the Splitter between the SC II and
the Tokheim cables.

Otherwise, connect the Splitter to the SC II and
put a C05878 adapter cable between the Splitter
and the Tokheim cables. Back-up the data, and
load the software.

Check jumper and configuration settings.

SC II Pump Configuration

In the PUMP configuration program, in submenu 1,
set Maximum Units to Gallons and Maximum
Amount to 999 Gallons.

In the PUMP configuration program, in submenu 3,
set the following options:

Tokheim type

Options to set

162/262 2,7

262-A 2,7,8,9,13

SA MMD

1,2,7,8,9

SA MMD $/Cr

1,2,3,7,8,9

TCS 1,2,7,8,9,13

TCS $/Cr

1,2,3,7,8,9,13

TCS 1 hose blend

1,2,7,8,9,12,13,19

TCS 1 hose blend $/Cr

1,2,3,7,8,9,12,13,19

TCS 1 hose, multigrade, non-blend

1,2,7,8,9,13,19

TCS 1 hose, multigrade non blend $/Cr 1,2,3,7,8,9,13,19

Premier 1,2,7,8,9,13,16

Premier $/Cr

1,2,3,7,8,9,13,16

Premier 1 hose blend

1,2,7,8,9,12,13,16,19

Premier 1 hose blend $/Cr

1,2,3,7,8,9,12,13,16,19

Premier blender

1,2,7,8,9,12,13,16

Premier blender $/Cr

1,2,3,7,8,9,12,13,16

Premier 1 hose, 1 prod

2,7,8,9,13,16

Premier 1 hose, 1 prod $/Cr

1,2,3,7,8,9,13,16

Premier 1 hose, multigrade

1,2,7,8,9,13,16,19

Premier 1 hose, multigrade $/Cr

1,2,3,7,8,9,13,16,19

The options in the above table are:

1 — Pump is a multi-product dispenser.

2 — Pump always needs switch detect (off-hook) to
activate.

3 — Pump has a cash-credit select button. (Customer
can choose cash or credit payment at the pump.)

4 — Site Controller can activate the pump without
knowing the price or hose (for some MPDs).

5 — Site Controller cannot choose the hose number
or price (for some MPDs).

6 — Site Controller cannot get the dollar amount or
volume during pumping.

7 — Pump can’t do switch detect or pulser timeouts
(timeouts must be done by the driver).

8 — Pump is a Tokheim stand-alone dispenser.

9 — Pump can only be activated from downloaded
prices (the displayed prices are downloaded).

10 — Pump never needs switch detect to activate
(can be activated while it is still on-hook).

11 — The PCU is slow to respond to requests
(improves performance on pumps that are inherently
slow to respond or at sites that have a large number
of pumps and are very busy).

12 — The pump is a blender. (The Site Controller
may not be able to keep component product tank
inventories for types of blender pumps that are not
specifically supported by Gasboy.) Do not use this
option for Gilbarco Blenders
.

13 — The pump is a TCS configured to always
download prices. (This allows TCS pumps to display
the correct price level for a sale, provided that the
pump’s Tokheim firmware supports the Mode 25
feature.)

14 — Pump is a Gasboy PAC.

15 — Single-sided pump (used for PCU auto-
configuration).

16 — Tokheim Premier model.

17 — Requires start button (not required for
Tokheim).

18 — Beeps without pressing payment on DPT or
CRIND.

19 — Grade-select buttons exist.

20 — Beeps when offhook without START key
being pressed.

21 — Pump has a lift-lever for offhook.

22 — Pump is the master of the pump chain. Turning
on this pump activates all other “pumps” in its cluster
except other master pumps in that cluster.