CFN II Quick Reference

48

C09159 Rev. 2238

RS485 loops. This sets the communication
parameters to 9600, odd, 1 stop bit, 7 data bits, and
security code to 000001. These parameters can also
be changed individually. You need a C07476 cable to
connect from the monitor to the 485/232 converter
(C05897).

Gasboy Interface Software

EECO SYSTEM™ 2000

Software

Minimum Revision

028 E

029 E

030 D

041 D

042 A

074 F

EECO SYSTEM™ 1500

Software

Minimum Revision

023 M

087 B

083 E

EECO SYSTEM™ Galaxy

Software

Minimum Revision

063 H

075 L

RS-422

Communications

422 Line Monitor

PC Monitor

There are no switches on the PC-based monitor. (DIP
Switch Banks 2 and 3, discussed below, apply only to
Site Controller I-based monitors.) PC monitors
require a 422-232 converter, discussed below after
DIP switch banks.

Help. Press H for help on the PC.

DIP Switch Banks 2 and 3

These switches apply only to Site Controller I-based
monitors. Set these switches according to the speed
of the terminal to be hooked to the line monitor.

Local Terminal Baud Rate

Baud Rate

3-1

3-2

2-8

300 closed

closed ____

1200 closed open ____

2400 open closed

closed

4800 open closed open

9600 open open ____

RS-422 Port Baud Rate

DIP switch 3, positions 5-8, all open=9600 baud.

DIP switch 2, position 7, open=7 bits; closed=8 bits.

422-232 Converter

For PC monitors, Veeder-Root tank gauges, and
Profit Points. Part number: C05897.

Jumpers

Position 1 is top and position 2 is bottom when the
board is oriented so that GASBOY RS422-RS232
CONVERTER is readable.

Position 1, both jumpers on upper two
rows:

Position 2, both jumpers on lower two
rows:

Jumper

Setting

Setting

Default

K1K2 position

1=slave

side of 422 loop
transmits

position 2=master
side of 422 loop
transmits

position

1

K3K4

position 1=tank
monitor or PC or
Profit Point

position 2=other
application if posi-
tion 1 doesn’t work

position

1

K5 always

on

on

K6

on=232 device lis-
tens to slave
responses, or for
PC monitor

off=tank gauge
off=Profit Point

off

K7

on=232 device
listens to master
side of 422 loop

on

R1 - Adjusting

R1 should be adjusted only if you are using a PC
monitor and the data being displayed is scrambled.

1. Turn R1 20 full turns counterclockwise.

2. Slowly turn R1 clockwise until the data display

clears up.