Getting Started/Troubleshooting
8-3
AMB Timing Software Interface
(Continued from previous page)
Symptom/Condition
Possible Cause/Corrective
Action
Matrix display is not updating
Make sure the transponder
software is currently running a
race.
Use the Refresh command
specified above for the
transponder software, and verify
position data is being received by
watching the console LCD cycle
through positions automatically.
• If no position data is
received, check connections
between the All Sport 5100
and transponder computer.
Also check the transponder
software communication
settings (see Section 6.2:
Transponder Software
Information immediately
preceding this table).
• If position data is received,
check connections between
the All Sport 5100 and
display.
Display information is incorrect
Restart the All Sport 5100 using
the <
MENU/NEW RACE
> option.
This will blank the scoreboard.
Follow the procedure in the
Transponder Settings section
preceding this table to refresh the
console with race information.
Verify that the RTD sequence on
the Venus controller includes
correct fields (see All Sport 5100
RTD Item Numbers and specific
controller documentation).
Verify all transponder software
settings as listed in Section 6.2:
Transponder Software
Information.