beautypg.com

Comtech EF Data MM200 User Manual

Page 35

background image

MM200 High-Speed Microwave Modem

User Interfaces

TM086 - Rev. 4.1

4-11




JIT CONTROL




NULL PID












CLK POLARITY



DATA INVERT



TERR LOOP



PRBS







BUFF ENABLE




CLK SOURCE





CLK FREQ



BUFF DEPTH (MS)


Note: Only appears when supported
by the installed interface.


{INCH, SLOW, MEDIUM, FAST,
STAMP2, STAMP3}
Clock recovery DLL speed, or Time-
Stamped packets.

{2-Byte Packet ID}
Defines the 2-byte packet ID, program ID
for null padding packets. This number
must match the corresponding receive
demux null PID. This number must be
unique and not be duplicated by an
interface PID or any DVB transport stream
PIDs on a framed interface.

Note: Only appears when using DVB
Framed Interfaces such as L0I.


{Normal, Inverted}
Sets the polarity of the clock.
Note: Only appears when supported
by the installed interface.


{Normal, Inverted}
Sets the polarity of the data.
Note: Only appears when supported
by the installed interface.


{Normal, Loopback}
Interface Loopback

{Normal, Ones, PAT001, PRBS2047}
Breaks the data path and inserts a pseudo
random sequence into the modulators.
‘None’ is used for normal operation, the
others are for Radyne Inc. Corporation
configuration.

{Disable, Enable}
Not currently implemented, for future
expansion.

{RxClk, Ext BNC, Ext Bal, Internal,
TxCLK}
Not currently implemented, for future
expansion.

{2.048 MHz, 5.0 MHz, 10.0 MHz, Data
Rate}
Not currently implemented, for future
expansion.

Not currently implemented, for future
expansion.



RW




RW











RW




RW



RW

RW





RW


RW



RW




RW