Comtech EF Data MM200 User Manual
Page 166

Appendix B
MM200 High-Speed Microwave Modem
B-18
TM086 – Rev. 4.1
0 = Mask, 1 = Allow"
::= { radMM200DemodNVStatus 15 }
radMM200RxAcquisitionControl OBJECT-TYPE
SYNTAX INTEGER {
off(1),
acquire(2)
}
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Enables acquisition and tracking."
::= { radMM200DemodNVStatus 16 }
radMM200RxAcquisitionBandwidth OBJECT-TYPE
SYNTAX INTEGER (50..400)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Sets the +/- acquisition range in KHz, 1 KHz steps."
::= { radMM200DemodNVStatus 17 }
radMM200RxAcquisitionDelay OBJECT-TYPE
SYNTAX INTEGER (10..255)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Sets the time the demodulator remains at frequency before
trying the next step. Delay is in secs."
::= { radMM200DemodNVStatus 18 }
radMM200RxReacquisitionDelay OBJECT-TYPE
SYNTAX INTEGER (10..255)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Sets the time the demodulator remains at frequency after
it first looses lock. Delay is in secs."
::= { radMM200DemodNVStatus 19 }
radMM200AcquisitionStep OBJECT-TYPE
SYNTAX INTEGER (10..100)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Sets the frequency step size the demodulator will take when
trying to acquire. Steps are in KHz."
::= { radMM200DemodNVStatus 20 }
radMM200TrackingStep OBJECT-TYPE
SYNTAX INTEGER (10..100)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Sets the step size the demodulator will use to remove the frequency
error of a locked signal. Normally set to 10Hz. Steps are in Hz."
::= { radMM200DemodNVStatus 21 }
-- ---------------------------------------------------------------------------------------------------------------------
-- ---------------------------------------------------------------------------------------------------------------------
-- MM200 demodulator status information.
radMM200RxMajorAlarm1Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-only
STATUS current
DESCRIPTION