Appendix A

MM200 High-Speed Microwave Modem

A-30

TM086 – Rev. 4.1










<1>











Reserved

4 = T3E3
5 = T1E1
6 = DSO
7 = PAR
8 = OC3
9 = HSSI
10 = SMPTE
11 = P10BaseT
12 = T2E2

Spare


Opcode: <0x2143>

Query selected Tx interface jitter control

Command Data Field 1 Byte

<1>

Selected interface
number

0 = interface1
1 = interface2
2 = interface3
3 = interface4

Query Response

<1>




<1>

Selected
interface number



Jitter Control

0 = interface1
1 = interface2
2 = interface3
3 = interface4

0 = Normal, 1 = Stamp2, 2 = Stamp3


Opcode: <0x2160>

Query selected Rx interface status

Command Data Field 1 Byte

<1>

Selected interface
number

0 = interface1
1 = interface2
2 = interface3
3 = interface4

Query Response

<1>




<1>



<1>







<1>



<1>

Selected
interface number



Interface Major
Alarm1


Interface Minor
Alarm1 Status






Interface Latched
Major Alarm1 Status


Interface Latched

0 = interface1
1 = interface2
2 = interface3
3 = interface4

0 = Pass, 1 = Fail
Bit 0 = Interface Test
Bit 1 - 7 = Spare

0 = Pass, 1 = Fail
Bit 0 = Interface FIFO full
Bit 1 = Interface FIFO empty
Bit 2 = PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect
Bit 5 - 7 = Spare

0 = Pass, 1 = Fail
Bit 0 = Interface Test
Bit 1 - 7 = Spare