Remote rllp – Comtech EF Data MM200 User Manual
Page 101

MM200 High-Speed Microwave Modem
Appendix A
TM086 – Rev. 4.1
A-1
Remote RLLP
A
When new features are added to Radyne equipment, the control parameters
are appended to the end of the Non-Volatile Section of the Remote
Communications Specification, and status of the features, if any, are added
at the end of the Volatile Section. If a remote M&C queries two pieces of
Radyne equipment with different revision software, they could respond
with two different sized packets. The remote M&C MUST make use of the
non-volatile count value to index to the start of the Volatile Section. If the
remote M&C is not aware of the newly added features to the product, it
should disregard the parameters at the end of the Non-Volatile Section and
index to the start of the Volatile Section.
Before creating any software based on the information contained in this
document, contact the Radyne Customer Service Department
(602-437-9620) to find out if the software revision for that piece of
equipment is current and that no new features have been added since the
release of this document.
A.1 MM200 Opcode Command Set
The MM200 Opcode Command Set is listed below:
A.2 Modem Command Set
Command
Opcode
Description
Query Identification
0x2000
Returns Device ID
Query Control Mode
0x2001
Returns current MM200 control mode
Query Revision Number
0x2002
Returns software revision number
Query Firmware Part Number
0x2003
Return firmware part number and release date
Query Time
0x2004
Returns current time
Query Date
0x2005
Returns current date
Query Time and Date
0x2006
Returns current time and date
Query Current Summary Alarms
0x2010
Returns current summary alarms
Query Latched Summary Alarms
0x2011
Returns latched summary alarms
Query Common Configuration
0x203E
Query the MM200 for the common