Comtech EF Data MM200 User Manual
Page 156

Appendix B
MM200 High-Speed Microwave Modem
B-8
TM086 – Rev. 4.1
"MM200 Tx channel non-volatile status structure"
INDEX { radMM200TxChannelNVIndex }
::= { radMM200TxChannelNVStatusTable 1 }
RadMM200TxChannelNVStatusEntry ::=
SEQUENCE
{
radMM200TxChannelNVIndex INTEGER,
radMM200TxChannelMajorAlarmMask INTEGER,
radMM200TxChannelMinorAlarmMask INTEGER
}
radMM200TxChannelNVIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Index into the MM200 Tx channel non-volatile table."
::= { radMM200TxChannelNVStatusEntry 1 }
radMM200TxChannelMajorAlarmMask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Major Alarm mask:
Bit 0 = Mod daughter board FPGA status
Bit 1 = RF PLL lock detect status
Bit 2-7 = Spares
0 = Mask, 1 = Allow"
::= { radMM200TxChannelNVStatusEntry 2 }
radMM200TxChannelMinorAlarmMask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Minor Alarm mask:
Bit 0 = Loop lock status
Bit 1 = FEC lock status
Bit 2 = FIFO full status
Bit 3 = FIFO empty status
Bit 4 = FIFO active
Bit 5-7 = Spares
0 = Mask, 1 = Allow"
::= { radMM200TxChannelNVStatusEntry 3 }
-- --------------------------------------------------------------------------------------------------------------------
-- --------------------------------------------------------------------------------------------------------------------
-- MM200 modulator channel status information.
radMM200TxChannelStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadMM200TxChannelStatusEntry
MAX-ACCESS
not-accessible
STATUS mandatory
DESCRIPTION
"MM200 Tx channel volatile status Table"
::= { mm200MIBObjects 4 }
radMM200TxChannelStatusEntry OBJECT-TYPE
SYNTAX RadMM200TxChannelStatusEntry
MAX-ACCESS
not-accessible
STATUS current
DESCRIPTION
"MM200 Tx channel volatile status structure"
INDEX { radMM200TxChannelIndex }
::= { radMM200TxChannelStatusTable 1 }