Comtech EF Data MM200 User Manual
Page 164
![background image](https://www.manualsdir.com/files/778780/content/doc164.png)
Appendix B
MM200 High-Speed Microwave Modem
B-16
TM086 – Rev. 4.1
radMM200RxIFUser3Frequency OBJECT-TYPE
SYNTAX INTEGER (50000000..90000000)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects IF user 3 frequency in Hz."
::= { radMM200DemodNVStatus 4 }
radMM200RxIFUser4Frequency OBJECT-TYPE
SYNTAX INTEGER (50000000..90000000)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects IF user 4 frequency in Hz."
::= { radMM200DemodNVStatus 5 }
radMM200RxIFSeperation OBJECT-TYPE
SYNTAX INTEGER (100..150)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects IF frequency separation in percent. It is
the additional bandwidth percentage the carrier
will cover over the original symbol rate. The range
is 100% to 150%."
::= { radMM200DemodNVStatus 6 }
radMM200RxDataRate OBJECT-TYPE
SYNTAX INTEGER (7000000..200000000)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects the data rate in BPS. The data rate is
variable from 7 Mbps to 200 Mbps."
::= { radMM200DemodNVStatus 7 }
radMM200RxSymbolRate OBJECT-TYPE
SYNTAX INTEGER (3500000..28000000)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects the data rate in BPS. The data rate is
variable from 3.5Mbps to 28Mbps."
::= { radMM200DemodNVStatus 8 }
radMM200RxDemodulation OBJECT-TYPE
SYNTAX INTEGER {
qam4(1),
qam16(2),
qam32(3),
qam64(4),
qam128(5),
qam256(6)
}
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects the QAM demodulation type."
::= { radMM200DemodNVStatus 9 }
radMM200RxSpectrum OBJECT-TYPE
SYNTAX InversionType
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Inverts the direction of rotation for the demodulation."