radMM200TxInterfaceStatusEntry OBJECT-TYPE
SYNTAX RadMM200TxInterfaceStatusEntry
MAX-ACCESS
not-accessible
STATUS current
DESCRIPTION
"MM200 Tx interface volatile status structure"
INDEX { radMM200TxInterfaceIndex }
::= { radMM200TxInterfaceStatusTable 1 }
RadMM200TxInterfaceStatusEntry ::=
SEQUENCE
{
radMM200TxInterfaceIndex INTEGER,
radMM200TxInterfaceMajorAlarmStatus INTEGER,
radMM200TxInterfaceMinorAlarmStatus INTEGER,
radMM200TxInterfaceLatchedMajorAlarmStatus INTEGER,
radMM200TxInterfaceLatchedMinorAlarmStatus INTEGER,
radMM200TxInterfaceCard INTEGER
}
radMM200TxInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Index into the MM200 Tx interface volatile table."
::= { radMM200TxInterfaceStatusEntry 1 }
radMM200TxInterfaceMajorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Major Alarm status:
Bit 0 = Interface test
Bit 1-7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200TxInterfaceStatusEntry 2 }
radMM200TxInterfaceMinorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Minor Alarm status:
Bit 0 = Interface FIFO full
Bit 1 = Interface FIFO empty
Bit 2 = Interface PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect
Bit 5 = Interface Tx input framing valid, added for AASI
Bit 6 = Interface signal loss, valid for some interfaces
Bit 7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200TxInterfaceStatusEntry 3 }
radMM200TxInterfaceLatchedMajorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Major Alarm status:
Bit 0 = Interface test
Bit 1-7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200TxInterfaceStatusEntry 4 }