beautypg.com

Comtech EF Data MM200 User Manual

Page 132

background image

Appendix A

MM200 High-Speed Microwave Modem

A-32

TM086 – Rev. 4.1








<1>


<1>




<1>




<1>





<1>


<1>


<1>


<1>

<1>


<1>






<1>



<1>









Interface Sub
Type

Interface Clock
Source



Interface Clock
Frequency



Interface
Framing




Interface Volume


Interface Clock
Polarity

Interface Data
Polarity

Reserved

Interface
Terrestrial Loopback

Interface PRBS






Interface Major
Alarm1 Mask


Interface Minor
Alarm1 Mask

14 = SMPTE19
15 = SMPTE 38
16 = P 10BaseT
17 = E2 UNBAL
18 = T2 UNBAL
19 = T2 BAL
20 = DS0 APC

Reserved, selects the Rx interface sub-type


0 = Rx Clk
1 = Ext BNC
2 = Ext Bal
3 = Internal Clk

0 = 2.048 MHz
1 = 5.0 MHz
2 = 10.0 MHz
3 = Data Rate

0 = unframed
1 = MPEG 188
2 = MPEG 204
3 = Null 188
2 = Null 204

0 - 255


0 = normal
1 = inverted

0 = normal, 1 = inverted


Spare

0 = disable, 1 = enable


0 = normal
1 = prbs_23
2 = prbs_23m
3 = prbs_15
4 = prbs_15m
(Not Yet Implemented)

0 = Mask, 1 = Allow
Bit 0 = Interface Test
Bit 1 - 7 = Spare

0 = Mask, 1 = Allow
Bit 0 = Interface FIFO full
Bit 1 = Interface FIFO empty
Bit 2 = PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect