MM200 High-Speed Microwave Modem
Appendix B
TM086 – Rev 4.1
B-31
radMM200CommonAlarm1Mask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Common Alarm 1 mask:
Bit 0 = Glue logic FPGA status
Bit 1 = Test FPGA status
Bit 2-7 = Spares
0 = Mask, 1 = Allow"
::= { radMM200CommonNVStatus 5 }
radMM200CommonAlarm2Mask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Common Alarm 2 mask:
Bit 0..7 = Spares
0 = Mask, 1 = Allow"
::= { radMM200CommonNVStatus 6 }
radMM200CommonResetSNMP OBJECT-TYPE
SYNTAX
INTEGER (123456789)
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"Forces the SNMP agent to re-initialize and restart."
::= { radMM200CommonNVStatus 7 }
radMM200CommonLatchedAlarmsClear OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Any write to this object clears the latched alarms."
::= { radMM200CommonNVStatus 8 }
-- --------------------------------------------------------------------------------------------------------------------
-- --------------------------------------------------------------------------------------------------------------------
-- MM200 common non-volatile status information.
radMM200CommonAlarm1Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B
Bit 0 = Glue logic FPGA status
Bit 1 = Test FPGA status
Bit 2-7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200CommonStatus 1 }
radMM200CommonAlarm2Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B
Bit 0..7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200CommonStatus 2 }