Appendix B

MM200 High-Speed Microwave Modem

B-4

TM086 – Rev. 4.1

DESCRIPTION

"Inverts the direction of rotation for the modulation."

::= { radMM200ModNVStatus 12 }


radMM200TxCarrierMode OBJECT-TYPE

SYNTAX INTEGER {

normal(1),
cw(2),
offset1hz(3),
khz100(4),
mhz35(5),
sweepUp(6),
sweepDown(7)
}

MAX-ACCESS

read-write

STATUS current

DESCRIPTION

"Normal sets the carrier to normal
CW causes the modulator to output pure carrier
Offset 1Hz
100 KHz
3.5 MHz
Sweep up
Sweep down"

::= { radMM200ModNVStatus 13 }


radMM200TxChannelSetting OBJECT-TYPE

SYNTAX INTEGER {

oneChannel(2),
twoChannel(3),
threeChannel(4),
fourChannel(5)
}

MAX-ACCESS

read-write

STATUS current

DESCRIPTION

"Selects the total number of channels in the MM200.
Automatic selection allows the MM200 to use the
maximum number of channels."

::= { radMM200ModNVStatus 14 }


radMM200TxMajorAlarm1Mask OBJECT-TYPE

SYNTAX AlarmByteType

MAX-ACCESS

read-write

STATUS current

DESCRIPTION

"Major Alarm 1 mask:
Bit 0 = Glue logic FPGA fail
Bit 1 = Data FPGA fail
Bit 2-7 = Spares
0 = Mask, 1 = Allow"

::= { radMM200ModNVStatus 15 }


radMM200TxMajorAlarm2Mask OBJECT-TYPE

SYNTAX AlarmByteType

MAX-ACCESS

read-write

STATUS current

DESCRIPTION

"Major Alarm 2 mask:
Bit 0-7 = Spares
0 = Mask, 1 = Allow"

::= { radMM200ModNVStatus 16 }


radMM200TxMinorAlarm1Mask OBJECT-TYPE

SYNTAX AlarmByteType

MAX-ACCESS

read-write

STATUS current