Comtech EF Data MM200 User Manual
Page 152
Appendix B
MM200 High-Speed Microwave Modem
B-4
TM086 – Rev. 4.1
DESCRIPTION
"Inverts the direction of rotation for the modulation."
::= { radMM200ModNVStatus 12 }
radMM200TxCarrierMode OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
cw(2),
offset1hz(3),
khz100(4),
mhz35(5),
sweepUp(6),
sweepDown(7)
}
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Normal sets the carrier to normal
CW causes the modulator to output pure carrier
Offset 1Hz
100 KHz
3.5 MHz
Sweep up
Sweep down"
::= { radMM200ModNVStatus 13 }
radMM200TxChannelSetting OBJECT-TYPE
SYNTAX INTEGER {
oneChannel(2),
twoChannel(3),
threeChannel(4),
fourChannel(5)
}
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects the total number of channels in the MM200.
Automatic selection allows the MM200 to use the
maximum number of channels."
::= { radMM200ModNVStatus 14 }
radMM200TxMajorAlarm1Mask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Major Alarm 1 mask:
Bit 0 = Glue logic FPGA fail
Bit 1 = Data FPGA fail
Bit 2-7 = Spares
0 = Mask, 1 = Allow"
::= { radMM200ModNVStatus 15 }
radMM200TxMajorAlarm2Mask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Major Alarm 2 mask:
Bit 0-7 = Spares
0 = Mask, 1 = Allow"
::= { radMM200ModNVStatus 16 }
radMM200TxMinorAlarm1Mask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-write
STATUS current