Comtech EF Data MM200 User Manual
Page 175
MM200 High-Speed Microwave Modem
Appendix B
TM086 – Rev 4.1
B-27
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"Sets the volume on the audio channel on the DS0
interfaces"
::= { radMM200RxInterfaceNVStatusEntry 10 }
radMM200RxInterfaceClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2),
}
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects clock polarity for Tx terrestrial clock
relative to Tx data."
::= { radMM200RxInterfaceNVStatusEntry 11 }
radMM200RxInterfaceDataInvert OBJECT-TYPE
SYNTAX InversionType
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects data polarity"
::= { radMM200RxInterfaceNVStatusEntry 12 }
radMM200RxInterfaceTerrestrialLoopback OBJECT-TYPE
SYNTAX ControlType
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Enables or disables Rx Interface Terrestrial Loopback."
::= { radMM200RxInterfaceNVStatusEntry 13 }
radMM200RxInterfacePRBS OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
prbs23(2),
prbs23m(3),
prbs15(4),
prbs15m(5)
}
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects the pseudo-random bit sequence for Rx
interface link testing."
::= { radMM200RxInterfaceNVStatusEntry 14 }
radMM200RxInterfaceMajorAlarmMask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Major Alarm mask:
Bit 0 = Interface test
Bit 1-7 = Spares
0 = Mask, 1 = Allow"
::= { radMM200RxInterfaceNVStatusEntry 15 }
radMM200RxInterfaceMinorAlarmMask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Minor Alarm mask: