RadMM200TxChannelStatusEntry ::=
SEQUENCE
{
radMM200TxChannelIndex INTEGER,
radMM200TxChannelMajorAlarmStatus INTEGER,
radMM200TxChannelMinorAlarmStatus INTEGER,
radMM200TxChannelLatchedMajorAlarmStatus INTEGER,
radMM200TxChannelLatchedMinorAlarmStatus INTEGER,
radMM200TxChannelBaudRate INTEGER,
radMM200TxChannelBaudState INTEGER
}
radMM200TxChannelIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Index into the MM200 Tx channel volatile table."
::= { radMM200TxChannelStatusEntry 1 }
radMM200TxChannelMajorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Major Alarm status:
Bit 0 = Mod daughter board FPGA status
Bit 1 = RF PLL lock detect status
Bit 2-7 = Spares
0 = PASS, 1 = FAIL"
::= { radMM200TxChannelStatusEntry 2 }
radMM200TxChannelMinorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Minor Alarm status:
Bit 0 = Loop lock status
Bit 1 = FEC lock status
Bit 2 = FIFO full status
Bit 3 = FIFO empty status
Bit 4 = FIFO active
Bit 5-7 = Spares
0 = PASS, 1 = FAIL"
::= { radMM200TxChannelStatusEntry 3 }
radMM200TxChannelLatchedMajorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Major Alarm status:
Bit 0 = Mod daughter board FPGA status
Bit 1 = RF PLL lock detect status
Bit 2-7 = Spares
0 = PASS, 1 = FAIL"
::= { radMM200TxChannelStatusEntry 4 }
radMM200TxChannelLatchedMinorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Minor Alarm status:
Bit 0 = Loop lock status
Bit 1 = FEC lock status
Bit 2 = FIFO full status