Opcode: <0x2208>

Command set common alarm mask

Command Data

<1>




<1>

Common Alarm1
Mask



Common Alarm2
Mask

0 = Mask, 1 = Allow
Bit 0 = Glue Logic FPGA Fail
Bit 1 = Test FPGA Fail
Bits 2 – 7 = Spare

0 = Mask, 1 = Allow
Bit 0 – 7 = Spare


Opcode: <0x2209>

Command set last rate control

Command Data

<1>

Last Rate Control

0 = Symbol
1 = Data
2 = Auto


Opcode: <0x220A>

Command frequency plan

Command Data

<1>

Frequency Plan

0 = Auto, 1 = User


Opcode: <0x220B>

Command user mode

Command Data

<1>

User Mode

0 = Reserved
1 = All Access
2 = Level 1
3 = Level 2
Note: Higher user levels restrict access to system control
parameters but allow higher levels of automation


Opcode: <0x220C>

Command mux loopback

Command Data

<1>

Mux Loopback

0 = Normal, 1 = Mux/Dmx Loop, 2 = Mux/Dmx LVDS,
3 = Modem LVDS, 4 = Repeater

Note: This command is not valid if the MM200 is in
Repeater Mode.


Opcode: <0x220D>

Command repeater mode

Command Data

<1>

Repeater Mode

0 = Off, 1 = On



Opcode: <0x2240>

Command modulator frequency

Command Data

<4>

IF Frequency

50000000 - 90000000


Opcode: <0x2241>

Command modulator data rate

Command Data

<4>

Data Rate

70000000 - 200000000