beautypg.com

Comtech EF Data MM200 User Manual

Page 120

background image

Appendix A

MM200 High-Speed Microwave Modem

A-20

TM086 – Rev. 4.1


<1>


<1>


<1>




<1>


<1>








<1>


<1>


<1>


<1>




<1>


<4>

<2>

<4>

<2>

Status

Minor Alarm1
Status

Minor Alarm2
Status

Common Alarm1
Status



Common Alarm2
Status

Latched Major
Alarm1 Status








Latched Major
Alarm2 Status

Latched
Minor Alarm1 Status

Latched Minor
Alarm2 Status

Latched Common
Alarm1 Status



Latched Common
Alarm2 Status

Max Payload

Utilization

Bandwidth

Input Level

Bits 0 – 7 = Spare

0 = Pass, 1 = Fail
Bits 0 – 7 = Spare

0 = Pass, 1 = Fail
Bits 0 – 7 = Spare

0 = M&C Mask, 1 = Allow
Bit 0 = Glue Logic CPLD Fail
Bit 1 = M&C Test FPGA Fail
Bits 2 – 7 = Spare

0 = Pass, 1 = Fail
Bits 0 – 7 = Spare

0 = Pass, 1 = Fail
Bit 0 = Glue Logic FPGA Fail
Bit 1 = Data FPGA Fail
Bit 2 = Signal Lock Detect
Bit 3 = Sync Lock Detect
Bit 4 = Deframer clock PLL lock detect
Bit 5 = Diversity FPGA fail
Bit 6 – 7 = Spare

0 = Pass, 1 = Fail
Bits 0 – 7 = Spare

0 = Pass, 1 = Fail
Bits 0 – 7 = Spare

0 = Pass, 1 = Fail
Bits 0 – 7 = Spare

0 = M&C Mask, 1 = Allow
Bit 0 = Glue Logic CPLD Fail
Bit 1 = M&C Test FPGA Fail
Bits 2 – 7 = Spare

0 = Pass, 1 = Fail
Bits 0 – 7 = Spare

Maximum payload at current demodulation

% utilization. Implied decimal point (i.e. 7985 means 79.85%)

Current bandwidth usage

Aggregate input level in dBm. Signed implied decimal point
(i.e. –265 means –26.5 dBm)


Opcode: <0x20BE>

Query a demodulator’s configuration

Query Response

<4>

<4>

Data Rate

Symbol Rate

7000000 - 200000000

3500000 - 28000000