Appendix A
TM086 – Rev. 4.1
A-27
<1>
<1>
<1>
<1>
<1>
<1>
<1>
<1>
Interface Volume
Interface Clock
Polarity
Interface Data
Polarity
Interface
Baseband Loopback
Reserved
Interface PRBS
Interface Major
Alarm1 Mask
Interface Minor
Alarm1 Mask
1 = MPEG 188
2 = MPEG 204
0 = 255
0 = normal
1 = inverted
2 = auto
0 = normal, 1 = inverted
0 = disable, 1 = enable
Spare
0 = normal
1 = prbs_23
2 = prbs_23m
3 = prbs_15
4 = prbs_15m
(Not Yet Implemented)
0 = Mask, 1 = Allow
Bit 0 = Interface Test
Bit 1 - 7 = Spare
0 = Mask, 1 = Allow
Bit 0 = Interface FIFO full
Bit 1 = Interface FIFO empty
Bit 2 = PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect
Bit 5 = Interface Tx input framing valid, added for AASI
Bit 6 = Interface signal loss, valid for some interfaces
Bit 7 = Spare
Opcode: <0x2142> Query selected Tx interface configuration and status
Command Data Field 1 Byte
<1>
Selected interface
number
0 = interface1
1 = interface2
2 = interface3
3 = interface4
Query Response
<1>
<1>
Selected interface
number
Number of
nonvol bytes*
* M&C developers
MUST use this
number of nonvolatile
0 = interface1
1 = interface2
2 = interface3
3 = interface4
Number of nonvol bytes for selected interface