Comtech EF Data MM200 User Manual
Page 151
MM200 High-Speed Microwave Modem
Appendix B
TM086 – Rev 4.1
B-3
DESCRIPTION
"Selects IF user 2 frequency in Hz."
::= { radMM200ModNVStatus 5 }
radMM200TxIFUser3Frequency OBJECT-TYPE
SYNTAX INTEGER (50000000..90000000)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects IF user 3 frequency in Hz."
::= { radMM200ModNVStatus 6 }
radMM200TxIFUser4Frequency OBJECT-TYPE
SYNTAX INTEGER (50000000..90000000)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects IF user 4 frequency in Hz."
::= { radMM200ModNVStatus 7 }
radMM200TxIFSeperation OBJECT-TYPE
SYNTAX INTEGER (100..150)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects IF frequency separation in percent. It is the additional
bandwidth percentage the carrier will cover over the original symbol
rate. The range is 100% to 150%."
::= { radMM200ModNVStatus 8 }
radMM200TxDataRate OBJECT-TYPE
SYNTAX INTEGER (7000000..200000000)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects the data rate in BPS. The data rate is variable from 7 Mbps
to 200 Mbps."
::= { radMM200ModNVStatus 9 }
radMM200TxSymbolRate OBJECT-TYPE
SYNTAX INTEGER (3500000..28000000)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects the symbol rate in SPS. The symbol rate is variable from 3.5Msps
to 28Msps."
::= { radMM200ModNVStatus 10 }
radMM200TxModulation OBJECT-TYPE
SYNTAX INTEGER {
qam4(1),
qam16(2),
qam32(3),
qam64(4),
qam128(5),
qam256(6)
}
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects the QAM modulation type."
::= { radMM200ModNVStatus 11 }
radMM200TxSpectrum OBJECT-TYPE
SYNTAX InversionType
MAX-ACCESS
read-write
STATUS current