beautypg.com

Comtech EF Data MM200 User Manual

Page 154

background image

Appendix B

MM200 High-Speed Microwave Modem

B-6

TM086 – Rev. 4.1

radMM200TxMinorAlarm1Status OBJECT-TYPE

SYNTAX AlarmByteType

MAX-ACCESS

read-only

STATUS current

DESCRIPTION

"A bit field. On startup, the agent initializes this to
the value '00000000'B
Bit 0 = Tx clock activity detect
Bit 1 = Tx data activity detect
Bit 2 = Frame lock
Bit 3 = Spare
Bit 4 = Spare
Bit 5 = Spare
Bit 6 = Spare
Bit 7 = Spare
0 = Pass, 1 = Fail"

::= { radMM200ModStatus 3 }


radMM200TxMinorAlarm2Status OBJECT-TYPE

SYNTAX AlarmByteType

MAX-ACCESS

read-only

STATUS current

DESCRIPTION

"A bit field. On startup, the agent initializes this to
the value '00000000'B
Bit 0..7 = Spares
0 = Pass, 1 = Fail"

::= { radMM200ModStatus 4 }


radMM200TxLatchedMajorAlarm1Status OBJECT-TYPE

SYNTAX AlarmByteType

MAX-ACCESS

read-only

STATUS current

DESCRIPTION

"A bit field. On startup, the agent initializes this
to the value '00000000'B.
Bit 0 = Glue logic FPGA fail
Bit 1 = Data FPGA fail
Bit 2-7 = Spares
0 = Pass, 1 = Fail"

::= { radMM200ModStatus 5 }


radMM200TxLatchedMajorAlarm2Status OBJECT-TYPE

SYNTAX

AlarmByteType

MAX-ACCESS

read-only

STATUS current

DESCRIPTION

"A bit field. On startup, the agent initializes this to
the value '00000000'B.
Bit 0..7 = Spares
0 = Pass, 1 = Fail"

::= { radMM200ModStatus 6 }


radMM200TxLatchedMinorAlarm1Status OBJECT-TYPE

SYNTAX AlarmByteType

MAX-ACCESS

read-only

STATUS current

DESCRIPTION

"A bit field. On startup, the agent initializes this to
the value '00000000'B.
Bit 0 = Tx clock activity detect
Bit 1 = Tx data activity detect
Bit 2 = Frame lock
Bit 3 = Spare
Bit 4 = Spare
Bit 5 = Spare
Bit 6 = Spare