ATEIS IDA8C User Manual
Page 438

Ateis Studio
438
© 2012 ATEÏS
Element Properties
Name
Initial
Minimum Maximum Precision
Unit
Trigger On
Off
-
-
-
-
Threshold
-20.0
-50.0
20.0
0.1
dB
Volume
-40.0
-40.0
20.0
0.1
dB
Response Time
0
0
500
10
ms
Hold Time
300
10
5000
10
ms
Element Description
Trigger On
Show the input signal is active or not. If the input signal continuously greater than Threshold over
Response Time, the trigger on value will be set to 1, and the corresponding logic output is set to
hi.
Threshold
The threshold to determine audio input is active or not.
Volume
The volume of the input signal.
Response Time
The time to determine audio input is active or not.
Hold Time
The time to determine audio input is active or not.