Use Logic Out component

By using Logic Out component, you can output signal coming from any logic component. please

refer to topic Logic Out component.

4.2

Consoles and Accessories

4.2.1 Redundancy Unit

4.2.1.1 Overview

PAVA systems in very highly sensitive places like nuclear power centrals, underground industrial

systems or places where people have to thrust on a 100% availability of a PAVA system, may require

for redundancy on any part of the PAVA system. Redundancy is a very widely-spread expression that

needs to be further specified into a required level of redundancy. In normal PAVA systems where other

communication means are available, spare amplifiers and surveillance of essential components is more

than enough. Higher levels of redundancy may require for A/B wiring of the loudspeaker lines where loss

of the A or B line or system still ensures a minimum coverage of 50% of the venue. (Such requirement is

detailed described in the BSI-5839 -part 8). But even that could not be enough in situations where the

PAVA is the only and last means of communication. In this case an even higher level of redundancy

may be required. At this level, not only the amplifiers have redundancy by means of active spare

amplifiers, also the central equipment will have a full back-up.

This is what we call: Full-Redundancy. AteÏs RU provides this high level of redundancy. RU is a thorough

switching device that acts as a Primary / Secondary switching device