Event – ATEIS IDA8C User Manual
Page 375

Components of Audio Processor
375
© 2012 ATEÏS
Parameters
Monitor Mode
There are two options:
o Voltage:
Logic output of component trigger by a voltage polarization change.
o Contact
Logic output of component trigger by a open or close the pin +/- of connector in rear panel.
Response Time
Determine how quick of the system response for changing of hardware status from Open(Lo) to
Close(Hi) or from Close(Hi) to Open(Lo).
Activation
Specify this parameter to determine what hardware condition generate 1 output. There are two
chooses:
o Open(Lo): Component output 1 when contact open(contact mode) or voltage low(voltage
mode), output 0 vise versa.
o Close(Hi): Component output 1 when contact close(contact mode) or voltage hi(voltage mode),
output 1 vise versa.
6.12.4 Event