Control panel – ATEIS IDA8C User Manual
Page 142

Ateis Studio
142
© 2012 ATEÏS
4.2.3.2 Control Panel
1. Microphone
The sleek condenser gooseneck microphone. This unidirectional condenser microphone warrants
high quality directive signal pick up from the user and hence less interference from the surroundings.
2. Monitoring Speaker
This embedded speaker to play chime when paging or monitor signal from audio processor, it needs
to work with rs485 output component to get audio signal from other DSP components in audio
processor.
3. Fault LED
To display fault status of system. Following table list the states of fault:
Status
Frequency
Activity
Permanent
There are faults in audio processor.
Blinking
° °
Lost communication with audio processor.
4. EVAC LED
Status
Frequency
Activity
Permanent
System is under evacuation paging.
Blinking
° °
PPM AS does not do a "Plug-in" in Ateis Studio before using.