Front panel – ATEIS IDA8C User Manual
Page 207

Product Features
207
© 2012 ATEÏS
A surveillance circuit continuously monitors the temperature and the presence of AC and DC power
supplies for both amplifiers. In case of a problem, the overload LEDs will be switched ON and the Fault
relay will be activated.
SPA series(SPA 2060, 2120, 2240) can be ordered with optional 115V power supply. Please contact
your local dealer or your regional ATEÏS branch office.
Specifications
Output power:
o SPA 2060 : 2 X 60W
o SPA 2120 : 2 X 120W
o SPA 2240 : 2 X 240W
Output voltage: 8 Ù, 70 & 100 V
Power indicate 24 V and 230 V: Yes
Frequency respond: 60 -18000 Hz
Distortion: < 1%
Output: 4-8 Ù 70-100 V
Fault contact(s): yes
Signal indication: Yes
4.3.1.2 Front Panel
Front Panel
VU Meter
The VU-meter is composed of three LEDs that represent three different level thresholds: -40dB, -
20dB and 0dB. When the input signal reaches those thresholds, the corresponding LED will blink.
Overload
The overload LED will blink as soon as the output power exceeds the nominal value. If the Overload
LED is blinking, check that the output load is well connected and still in good condition as well as