ATEIS IDA8C User Manual
Page 104

Ateis Studio
104
© 2012 ATEÏS
Get Reference
Get the reference values of selected zone for further fault detection. Be aware, hardware
configuration(IDA8C/S, amplifiers, wiring) should be done before get reference.
Reset Reference
Clear reference values of selected zone to go back initial status. if reference value is cleared,
monitoring will be stopped.
Measurement
After parameter settings are done in lower part grid, IDA8C/S start to measure value get from internal
circuit, and display it on the grid at upper part of window:
Unloaded Reference
Display the value of unloaded reference which is the gain of amplifier when there is no load to
the zone. This value use to determine if there is a fault of normal amplifier or not.
Full Loaded Reference
Display the value of full loaded reference which is the gain of amplifier when there is full load to
the zone. This value use to determine if there is a fault of normal amplifier or not.
Measure
Display the value of measured which is the gain of amplifier.
Faults
Amplifier Too High
If Measure > (Unloaded Reference x (100% + Tolerance%)), an Amplifier Too High fault is
recognized. once this fault is happen, do the following checks: