AMETEK i-iX Series II User Manual
Page 98

User Manual
California Instruments
98
i Series II / iX Series II / iM Series II
4.2.11.5 CONFIGURATION SETUP screens
Figure 4-25: CONFIGURATION SETUP Menus
The configuration setup screen is not a menu but only serves to inform the user of the software
options installed in the AC source. The cursor can be moved to any of the fields in this screen
but none of these fields can be changed. The following information is provided on this screen:
Entry
Description
CONFIGURATION SETUP 1
NO. OUTPUT
Displays the phase mode option. SELECT indicates the phase
mode option is installed and the user can select between single
and three phase modes of operation.
FIXED indicates the phase mode option is not installed and only
single phase or three phase mode of operation is possible.
ADVANCE
[iX models only] This field indicates the presence of advanced
capabilities for waveform generation and measurement analysis
are present.
DO160
Indicates the presence of the RTCA DO160 test option. If this
option is installed, this field will show ON. If this option is not
installed, this field will show N/A (not available).
MIL704
Indicates the presence of the MIL/STD-704 Revision D and E
test option. If this option is installed, this field will show ON. If
this option is not installed, this field will show N/A (not
available).
CONFIGURATION SETUP 2
IEC 4-11
Indicates the presence of the IEC 61000-4-11 test option. If this
option is installed, this field will show ON. If this option is not
installed, this field will show N/A (not available).
IEC 4-13
Indicates the presence of the IEC 61000-4-13 test option. If this
option is installed, this field will show ON. If this option is not
installed, this field will show N/A (not available).