4.2.11.3 INITIAL SETUP menu
Figure 4-23: INITIAL SETUP menus
Any time the AC source is powered up, the output will reflect the values stored as the INITIAL
setup values. This allows the unit to be powered up in a known state at all times. The INITIAL
values can be set in the INITIAL SETUP menus.
The initial setup can be used to power up the AC source with the output on and a high voltage
present at the output. For normal situations, this is not recommended due to the potential danger
to the operator. It is recommended that the initial voltage be set low and/or the output relay be
programmed to OFF for most situations.
The following fields are provided in the INITIAL SETUP menus:
Entry
Description
INITIAL SETUP 1
VOLTAGE
Sets the power-on AC voltage for AC and AC+DC modes or the
DC voltage for DC mode.
CURR LIMIT
Sets the power-on current limit value.
FREQ
Sets the power-on frequency value.
PHASE
Sets the power-on frequency for phase A with respect to an
external sync signal. If the internal oscillator is used (default)
this setting has no effect.
INITIAL SETUP 2
VOLT RANGE
Sets the power-on voltage range value. The available choices
are determined by the VOLT PAIR selected in the
VOLTAGE/CURRENT CONTROL SETUP menu.
VOLT MODE
Sets the power-on voltage mode. Available settings are AC
mode, DC mode or AC+DC mode [iX Series only].
OL MODE
Sets the power-on overload mode. Available settings are
Constant Current (CC) or Constant Voltage (CV) mode.
OUTPUT RELAY
Sets the power-on state of the output relay. Available settings
are ON or OFF.
INITIAL SETUP 3
VOLT SENSE
Sets the power-on state of the voltage sense mode. Available
settings are Internal (INT) or External (EXT).