beautypg.com

AMETEK i-iX Series II User Manual

Page 24

background image

User Manual

California Instruments

24

i Series II / iX Series II / iM Series II

Parameter

Range

Accuracy (

±

)

Resolution

Accuracy specifications apply above 100 counts. Current and Power Accuracy specifications are times two for
10001iX and times three for 15001iX. For 10001iX and 15001iX, resolution decreases by factor of 10, ranges for
current and power increases by factor of three.

2.1.5 Harmonic Measurements (iX series)

Parameter

Range

Accuracy (

±

)

Resolution

Frequency fundamental

16.00 - 1000 Hz

2 counts

0.01 Hz to 1 Hz

Frequency harmonics

32.00 Hz - 16 kHz

2

°

typ.

0.5

°

Voltage

Fundamental

0.25V

0.01V

Harmonic 2 - 50

0.25V + 0.1% + 0.1%/kHz

0.01V

Current

Fundamental

0.05A

0.01A

Harmonic 2 - 50

0.05A + 0.1% + 0.1%/kHz

0.01A

Accuracy specifications are times three for three phase mode. Harmonics frequency range in three-phase mode is 32
Hz - 16 kHz. Resolution decreases by factor of 10 for 10001iX and 15001iX.

2.1.6 System Specification

Parameter

Specification

External Modulation: 0 to 10%

Synchronization
Input:

Isolated TTL input for external frequency control. Requires 5V at 5 ma
for logic high.

Trigger Output:

400

µ

s pulse for voltage or frequency change. Isolated output that

requires a pull-up resistor, 22K

, to + 5 VDC.

Non volatile memory
storage:

16 complete instrument setups and transient lists, 100 events per list.

Waveforms

Sine (i series)
Sine, square, clipped, user defined (iX series)

Transients

Voltage: drop, step, sag, surge, sweep

(i/iX only)

Frequency: step, sag, surge, sweep

Voltage and Frequency: step, sweep

IEEE-488 Interface:

SH1, AH1, T6, L3, SR1, RL2, DC1, DT1
IEEE 488.2 and SCPI
Response time is 10 ms (typical)

RS232C Interface:

Bi-directional serial interface
9 pin D-shell connector
Handshake: CTS, RTS
Data bits: 7, 8
Stop bits: 1,2
Baud rate: 9600, 19200, 38400 (Models without USB I/F)
Baud rate: 9600, 19200, 38400, 57600, 115200, 230400, 460800
IEEE 488.2 and SCPI.