2.1.2 Output

(ALL SPECIFICATIONS ARE FOR AC AND DC UNLESS NOTED OTHERWISE)

Output Parameter

i / iM Series

iX Series

Modes:

AC, DC

AC, DC, AC+DC

Voltage:

Ranges (L-N):

AC Mode

Low:

0 - 150 VAC

High

1

: 0 - 300 VAC

DC Mode

Low:

0 - 200 VDC

High:

0 - 400 VDC

AC+DC Mode

iX Models only.

AC:

Low: 0 - 150 V / High: 0 - 300 V

(See footnote 1)

DC

Offset: Low 0 - 150 V / High; 0 - 225 V

Programming
Resolution:

AC Mode

0.1 V

DC Mode

0.1 V

AC+DC Mode

AC:

0.1 V

DC Offset:

0.1 V

Voltage Accuracy:

AC mode

±

0.5% of range, 16 to 400

Hz.

±

0.5% of range, 16 to 400 Hz.

DC mode

±

0.5% of range

±

0.5% of range

Voltage Distortion

2

:

(linear load)

1% max THD at 50/60 Hz
2% max THD at 400 Hz
3% max THD at 1000 Hz

1% max THD at 50/60 Hz
2% max THD at 400 Hz
3% max THD at 1000 Hz

Load Regulation (% FS
Vrange):

ALC on

±

0.2%

±

0.2%

ALC off

±

0.5% DC to 100 Hz

±

2.2% to 1000 Hz (Low

range)

±

0.6% to 1000 Hz (High

range)

±

0.5% DC to 100 Hz.

±

2.2% to 1000 Hz (Low range)

±

0.6% to 1000 Hz (High range)

Line Regulation:

0.1% for 10% input line
change

0.1% for 10% input line change

Power: (per phase, either range, at full scale voltage)

1

Maximum RMS voltage in high voltage range is a function of programmed frequency. For frequencies above 500

Hz, the maximum available Vrms = 1.5 E+4 / F. See Figure 2-9 for V-F rating.

2