beautypg.com

AMETEK i-iX Series II User Manual

Page 23

background image

User Manual

California Instruments

i Series II / iX Series II / iM Series II

23

Output Parameter

i / iM Series

iX Series

Output Noise:
(20 kHz to 1 MHz)

<250 mV rms (typ),

<500 mV rms (max)

<250 mV rms (typ),

<500 mV rms (max)

Peak Rep AC Current:

3001i/iX

5001i/iX

9003i/iX

15003i/iX

110 A for 150 V range,
92 A for 300 V range

110 A for 150V range,
92 A for 300 V range,

10001i/iX

220 A for 150 V range,
184 A for 300 V range

220 A for 150 V range,
184 A for 300 V range

15001i/iX

330 A for 150 V range,
276 A for 300 V range

330 A for 150 V range,
276 A for 300 V range

Crest Factor:

Up to 5:1

Up to 5:1

2.1.3 AC Measurements

Note: Measurements are not available on iM Series II models.

Parameter

Range

Accuracy (

±

)

Resolution

Frequency

16.00 - 1000 Hz

2 counts

0.01: 16 to 81.91 Hz
0.1: 82.0 to 819.0 Hz
1: 820 to 1000 Hz

RMS Voltage

0 - 300 Volts

0.25V + 0.1%, <100 Hz
0.25V + 0.2%, 100-1000 Hz

0.01 Volt

RMS Current

0 - 40 Amps

0.25A + 0.1%, <100 Hz
0.25A + 0.2%, 100-1000 Hz

0.001 Amp

Peak Current

0 - 119 Amps

0.5A + 0.2%, <100 Hz
0.5A + 0.5%, 100-1000 Hz

0.01 Amp

VA Power

0 – 6000 VA

10 VA + 0.1%, <100 Hz
20 VA + 0.2%, 100-1000 Hz

1 VA

Real Power

0 – 6000 W

10 W + 0.1%, <100 Hz
20 W + 0.2%, 100-1000 Hz

1 W

Power Factor
(>0.2kVA)

0 - 1.00

0.01

Accuracy specifications apply above 100 counts. Current and Power Accuracy specifications are times two for
10001iX and times three for 15001iX. For 10001iX and 15001iX, resolution decreases by factor of 10, ranges for
current and power increases by factor of three. Measurement bandwidth is limited to 16 Khz.

2.1.4 DC Measurements

Note: Measurements are not available on iM Series II models.

Parameter

Range

Accuracy (

±

)

Resolution

Voltage

0 – 400 Volts

0.4 Volts

0.01 Volt

Current

0 – 40 Amps

0.1 Amps

0.001 Amp

Power

0 – 6000 W

20 W

1 W