Output Parameter
i / iM Series
iX Series
3001, 9003i/iX
5001, 15003i/iX
10001i/iX
15001i/iX
3000 VA AC, 2100 W DC
5000 VA AC, 3500 W DC
10000 VA AC, 7000 W DC
15000 VA AC, 10500 W DC
3000 VA AC, 2100 W DC
5000 VA AC, 3500 W DC
10000 VA AC, 7000 W DC
15000 VA AC, 10500 W DC
Current, maximum amps per phase:
3001i/iX
22.2 Arms @ 135 VAC in 150 Vrange
11.1 Arms @ 270 VAC in 300 Vrange
15.5 Adc @ 135 VDC in 200 Vrange
7.77 Adc @ 270 VDC in 400 Vrange
5001 /15003i/iX
per phase
37.0 Arms @ 135 VAC in 150 Vrange
18.5 Arms @ 270 VAC in 300 Vrange
25.9 Adc @ 135 VDC in 200 Vrange
12.95 Adc @ 270 VDC in 400 Vrange
10001i/iX
74.0 Arms @ 135 VAC in 150 Vrange
37.0 Arms @ 270 VAC in 300 Vrange
51.8 Adc @ 135 VDC in 200 Vrange
25.9 Adc @ 270 VDC in 400 Vrange
10001i/iX
111 Arms @ 135 VAC in 150 Vrange
55.5 Arms @ 270 VAC in 300 Vrange
77.7 Adc @ 135 VDC in 200 Vrange
38.8 Adc @ 270 VDC in 400 Vrange
Current derates at higher voltage settings along constant power curve. See Figures Figure 2-1 through
Figure 2-8 for voltage current ratings per phase or output by model.
Maximum current for which specifications apply is derated linearly from 50% of voltage to 10% of
specified current at 5% of voltage range as shown. Higher currents are available but not all specification
will apply under these conditions.
Note: For the iX series, the current output in the AC & DC mode is equal to the current in the AC mode
if the DC voltage is less than 20% of the full scale voltage. It is equal to the DC current for DC voltages
more than 20% of full scale