AMETEK i-iX Series II User Manual
Page 26

User Manual
California Instruments
26
i Series II / iX Series II / iM Series II
2.2 Mechanical
Parameter
Specification
Dimensions:
19” (483 mm) wide x 7” (178 mm) high x 24” (610 mm) deep chassis
size which is available in a rack mount or stand-alone configuration.
Unit Weight:
61 lb. (28 kg)
Material:
Aluminum chassis, panels and cover.
Finish:
Light textured painted external surfaces.
Front and rear panels semi-gloss polyurethane color no. 26440
(medium gray)
Top, bottom and sides semi-gloss polyurethane color no. 26622 (light
gray).
Cooling:
Fan cooled with air intake on the sides and exhaust to the rear.
Internal
Construction:
Modular sub assemblies.
Rear Panel
Connections:
(see section 3 for description of connections)
Input terminal block with cover
Output terminal block with cover
Remote voltage sense terminal block
System interface (not for table top use, use only in rack enclosed
systems)
Clock and Lock (not for table top use, use only in rack enclosed
systems)
RS232, GPIB, USB, LAN (option)
2.3 Environmental
Parameter
Specification
Operating Temp:
0 to +40
°
C.
Storage Temp:
-40 to +85
°
C.
Altitude:
< 2000 m
Relative Humidity:
80% maximum for temperatures up to 31
°
C decreasing linearly to
50% at 40
°
C.
Installation/Over voltage
Category:
ΙΙ
Pollution Degree:
2
Indoor Use Only
Vibration:
Designed to meet NSTA 1A transportation levels.
Shock:
Designed to meet NSTA 1A transportation levels.