beautypg.com

AMETEK i-iX Series II User Manual

Page 248

background image

User Manual

California Instruments

248

i Series II / iX Series II / iM Series II

9.13 WHM Option

9.13.1 General

This section describes the WHM option for the i / iX Series Power Source.

9.13.2 Specification

All specifications are the same as the standard i / iX Power Source specifications in addition to
the following specifications:

Watt-hour

0-6.000KW

0.01KWH + 0.1% <100Hz

0.02KWH +0.1% 100-500Hz

>6.000KW

Times three of the above specification

9.13.3 Local Operation

From the Menu screen 2, select the APPLICATIONS SETUP 2 screen. The screen will appear
as shown in Figure 9-59. Use the up and down key to position the cursor to the WH METER
field. Press the Enter Key.

Figure 9-59: Application Screen

The WATT-HOURS METER screen shown in Figure 9-60 has the following fields:

Figure 9-60 Watt-Hour Meter Screen

START: This field will activate the watt-hour measurements. Moving the shuttle clockwise when
the field is highlighted will activate the watt hour function and the field will change to STOP as
shown in Figure 9-61.

1. ETIME: This field will accumulate the time in hours, minutes and seconds.

2. WATT HR: This field will accumulate the watt-hour in KWH.

3. POWER: This field will report the instantaneous power in KW.

4. PK CURR: This field will report the peak current and will hold the maximum reading.

Figure 9-61: WH-Meter Screen With Function Active