Frequency output – Echelon FT 3150 Smart Transceiver User Manual
Page 87
FT 3120 / FT 3150 Smart Transceiver Data Book
81
Timer/Counter Output Objects
Figure 3.44 Edgedivide Output Object
Frequency Output
A timer/counter may be configured to generate a continuous square wave of 50% duty cycle. Writing a new
frequency value to the device takes effect at the end of the current cycle. This object is useful for frequency synthesis
Symbol
Description
Min
Typ
Max
t
fout
Function call to start of timer
—
96 µs
—
t
fod
Function to output disable
—
82.2 µs
—
t
sod
Active sync edge to output toggle
550 ns
—
750 ns
t
win
Sync input pulse width (10MHz)
200 ns
—
—
t
ret
Return from function
—
13 µs
—
OUTPUT
SYNC INPUT
TIME
t
sod
START OF
io_out()
INTERNAL
COUNT
BEGINS
END OF
io_out()
START OF
io_out()
OUTPUT
INACTIVE
t
fod
t
fout
t
win
t
ret
Timer/Counter 1
Timer/Counter 2
IO10
IO9
IO8
IO0
IO1
IO2
IO3
IO4
IO5
IO6
IO7
mux
Output
Sync
Input
Optional Pull-Up Resistors
High Current Sink Drivers