Configure start/stop, genlock, timecode, tally, Red 3-axis system operation guide – RED 3-AXIS LENS CONTROL SYSTEM User Manual
Page 27

RED 3-AXIS SYSTEM OPERATION GUIDE
COPYRIGHT © 2014 RED.COM, INC
955-0044, REV-D | 27
CONFIGURE START/STOP, GENLOCK, TIMECODE, TALLY
This section explains how to set up start/stop, genlock, and timecode with the W.M.D. and a DSMC.
For more information about cables and configurations, go to
“3-Axis System Cables” on page 63
1. Configure Start/Stop in the DSMC menu.
A. Go to Menu > Settings > Setup > GPIO/Sync > Brain GPIO.
B. Select General Purpose In from the Camera In drop-down menu.
2. Connect the appropriate RED Start/Stop Cables for your desired configuration.
FUNCTIONS
CABLE
PART NUMBERS HOW TO CONNECT
Start/Stop,
Genlock,
Timecode,
and Tally
RED Start/Stop Cable
(1B to Sync, Ctrl, BNC)
790-0415
1. Connect the 14-pin 1B LEMO to the EXP
port on the W.M.D.
2. Connect the 4-pin LEMO start/stop con-
nector to the CTRL port on the DSMC
BRAIN
3. Connect the BNC connector to the
White BNC connector of the 3BNC-
to-00 LEMO Sync Cable using a BNC-
TO-BNC Adaptor (included with the
RED 3-Axis Lens Control System)
3BNC-to-00 LEMO Sync
Cable
790-0154
4. Connect the 4-pin 00 LEMO connector to
the SYNC port on the DSMC BRAIN
Start/Stop,
Genlock,
and Timecode
RED Start/Stop Cable
(1B to BNC)
790-0416
1. Connect the 14-pin 1B LEMO to the EXP
port on the W.M.D.
2. Connect the BNC connector to the
White BNC connector of the 3BNC-
to-00 LEMO Sync Cable using a BNC-
TO-BNC Adaptor (included with the
RED 3-Axis Lens Control System)
3BNC-to-00 LEMO Sync
Cable
790-0154
3. Connect the 4-pin 00 LEMO connector to
the SYNC port on the DSMC BRAIN
Start/Stop
RED Start/Stop Cable
(1B to 00B Sync)
790-0428
1. Connect the 14-pin 1B LEMO to the EXP
port on the W.M.D.
2. Connect the 4-pin 00 LEMO connector to