EVCO EVFTFT818P7U Installer manual User Manual

Page 63

background image

EVCO S.p.A.

EVFTFT818 | Installer manual ver. 2.1 | Code 144FTFT818E214

page 63 of 94

A4

0

99

°C/°F (1)

10

cabinet

temperature

above

which

the

maximum

temperature alarm is activated (relative to the work set-

point, i.e. “r10 +A4” during post blast chilling storage and

“r11 +A4” during post deep freezing storage; (“AH” code);

see also parameter A11 (4)

A5

0

1

- - - -

1

enabling of maximum temperature alarm (“AH” code)

1 = yes

A7

0

240

min

15

temperature alarm delay(“AL” code and “AH” code)

A8

0

240

min

15

maximum temperature alarm delay (“AH” code) from the

conclusion of evaporator fan stop and storage start-up

A10

0

240

min

5

duration of a power cut such to cause the power cut alarm

to be memorised ( “PF” code)when the power is supplied

0 = the alarm will not be signalled

AA

0

240

s

5

duration of buzzer activation on conclusion of blast chilling

and deep freezing

A11

1

15

°C/°F (1)

2

parameters A1 and A4 differential

A13

0

1

- - - -

1

memorisation of the temperature-controlled blast chilling or

temperature-controlled deep freezing non concluded within

maximum duration alarm (“tiM” code)

1 = yes

A14

- - - -

- - - -

- - - -

- - - -

riservato

Par.

Min.

Max.

Unit

Default

Evaporator and condenser fan