6 continuous blast chilling, 7 temperature-controlled deep freezing and storage – EVCO EVFTFT818P7U Installer manual User Manual
Page 33

EVCO S.p.A.
EVFTFT818 | Installer manual ver. 2.1 | Code 144FTFT818E214
page 33 of 94
6.6
Continuous blast chilling
Operate as indicated to start the cycle:
1.
Make sure the device is in the "on" status.
2.
Make sure that the keyboard is not locked and that no procedure is in progress.
3.
Press and release the
key (1), press and release the
key (2) and then press and release the
key (3)
twice. The device will display the work set-point during blast chilling.
4.1
Press and release the MENU key and then press and release the
key or the
key to select the work set-
point during blast chilling.
4.2
Press and release the
key or the
key to modify this value and then the ESCAPE key to memorise it; this
value can also be memorised through parameters r1 and r7.
5.
Press and release the START/STOP key (1): the cycle will be started.
During blast chilling the device displays the temperature of the cabinet, the program name (if envisioned) and the time
passed since the start of blast chilling.
Operate as indicated to stop the cycle:
6.
Press and hold the START/STOP key 3 s.
Parameter r7 establishes the work set-point during blast chilling.
6.7
Temperature-controlled deep freezing and storage
The temperature-controlled deep freezing and storage cycle is divided into the following two phases:
-
deep freezing
-
storage.
On conclusion of a phase, the device passes automatically to the next.
Operate as indicated to start the cycle: