7
“PROGRAMS” FUNCTION
7.1
Foreword
The programs function can be used to memorise some settings in a program and start an operating cycle with the
settings it has memorised.
Up to 99 programs can be memorised.
7.2
Memorisation of a program
Operate as follows:
1.
Make sure that the keyboard is not locked and that no procedure is in progress.
2.
Press and release the
key (1) before starting an operating cycle or during storage: the device will display
the number of the first program available.
2.1
If the
key is pressed and released before starting an operation cycle, the device will memorise the following
settings:
-
type of operating cycle selected
-
blast chilling/deep freezing intensity selected
-
if the key is pressed before starting-up a temperature-controlled cycle:
-
the work set-point during blast chilling and the blast chilling end temperature
-
if the key is pressed before starting-up a time-controlled cycle:
-
the work set-point during blast chilling and the blast chilling duration.
2.2
If the
key is pressed and released during storage, the device memorises the following settings:
-
type of operating cycle in progress
-
the duration of blast chilling or deep freezing, i.e. the time taken to successfully complete blast chilling
or deep freezing.
-
blast chilling/deep freezing intensity selected before starting an operating cycle.
-
the work set-point selected before starting up an operating cycle.
The execution of a program memorised by pressing and releasing the
key during storage causes the
start of a timed cycle.