beautypg.com

Chapter 6. maintenance, 1 maintenance schedule, Chapter 6 – AERCO Innovation (G-13-1854 and above) User Manual

Page 71: Maintenance

background image

Innovation Water Heaters Installation, Operation & Maintenance Manual

CHAPTER 6 – MAINTENANCE

OMM-0078_0J

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913

Page 71 of

196

GF-128

Phone: 800-526-0288

PRI: 11/22/2013

CHAPTER 6. MAINTENANCE

6.1 MAINTENANCE SCHEDULE

The Innovation Water Heater requires regular routine maintenance to ensure continued reliable
operation throughout the service life of the unit. For optimum operation, AERCO recommends
that the following routine maintenance procedures be performed in the time periods specified in
Table 6-1.

Appendix I contains a list of the recommended spare parts for maintenance of the Innovation
Heater.

TO AVOID PERSONAL INJURY, PRIOR TO SERVICING ENSURE THAT
THE FOLLOWING GUIDELINES ARE STRICTLY OBSERVED:

• DISCONNECT THE AC SUPPLY BY TURNING OFF THE SERVICE

SWITCH AND AC SUPPLY CIRCUIT BREAKER.

• SHUT OFF THE GAS SUPPLY AT THE MANUAL SHUT-OFF VALVE

PROVIDED WITH THE UNIT

• ALLOW THE UNIT TO COOL TO A SAFE WATER TEMPERATURE TO

PREVENT BURNING OR SCALDING

Table 6-1 - Maintenance Schedule

Section

Item

6 Mos.

12 Mos.

24 Mos.

Labor

Time

6.2

Igniter

(66023)

*Inspect

Inspect

Replace

15 mins.

6.3

Flame Detector

(66018)

*Inspect

Inspect

Replace

15 mins.

6.4

Combustion

Calibration

*Check

Check

1 hr.

6.5

Testing of

Safety Devices

Test

20 mins.

6.6

Fireside

Inspection

Inspect &

Clean

2 hrs.

6.7

Waterside
Inspection

*Inspect

Inspect

1 hr.

6.8

Heat Exchanger

Cleaning

Inspect &

Clean (as

required)

2 hrs.

6.9

Condensate

Drain Trap

*Inspect

Inspect &

Clean

30 mins.

6.10

Air Filter

(59138)

Clean or

Replace

5 mins.

*

Only performed after initial 6 month period after initial startup.

WARNING