beautypg.com

AERCO Innovation (G-13-1854 and above) User Manual

Page 108

background image

Innovation Water Heaters Installation, Operation & Maintenance Manual

CHAPTER 8 – RS232 COMMUNICATION

Page 108 of

196

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913

OMM-0078_0J

PRI: 11/22/2013

Phone: 800-526-0288

GF-128

Table 8-3 shows a sample Sensor Log every 5 minutes for a heater running in Constant Setpoint
mode.

Table 8-3. Sample Sensor Log Display

Setpt Outlet Outdr FFWD Aux Inlet Exhst CO O2

Flow Date

Time

130 181 OPEN OPEN OPEN OPEN OPEN 0 .0 0 1/15/02 5:51pm

130 180 OPEN OPEN OPEN OPEN OPEN 0 .0 0 1/15/02 5:46pm

130 180 OPEN OPEN OPEN OPEN OPEN 0 .0 0 1/15/02 5:41pm

130 179 OPEN OPEN OPEN OPEN OPEN 0 .0 0 1/15/02 5:36pm

130 180 OPEN OPEN OPEN OPEN OPEN 0 .0 0 1/15/02 5:31pm

130 180 OPEN OPEN OPEN OPEN OPEN 0 .0 0 1/15/02 5:26pm

130 180 OPEN OPEN OPEN OPEN OPEN 0 .0 0 1/15/02 5:21pm

130 180 OPEN OPEN OPEN OPEN OPEN 0 .0 0 1/15/02 5:16pm

130 179 OPEN OPEN OPEN OPEN OPEN 0 .0 0 1/15/02 5:11pm

130 180 OPEN OPEN OPEN OPEN OPEN 0 .0 0 1/15/02 5:06pm