Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual
Page 34

Configuration
28
Level 3 Submenus
EDP Port
BAUD
9600
19200
300
600
1200
2400
4800
Baud rate. Selects the transmission speed for the EDP port.
BITS
8NONE
7EVEN
7ODD
Selects number of data bits and parity of data transmitted from the EDP port.
TERMIN
CR/LF
CR
Termination character. Selects termination character for data sent from the EDP port.
ECHO
ON
OFF
Allows the echo to be turned on or off.
EOLDLY
0000000
0–255
End-of-line delay. Sets the delay period, in 0.1-second intervals, from when a formatted line is
terminated to the beginning of the next formatted serial output. Value specified must be in the
range 0-255, in tenths of a second (10 = 1 second).
HANDSHK
OFF
ON
Specifies whether XON/XOFF flow control characters are used.
ADDRESS
0000000
0–255
Specifies the decimal indicator address for RS-485 connections. RS-232 communications is
disabled if an address other than zero is specified for this parameter. RS-485 addresses must be
in the range 0–255.
STREAM
OFF
LFT
IND
Specifies whether data is streamed from the EDP port.
OFF: Data is not streamed from the EDP port
LFT (Legal-for-Trade): Data is streamed at the display update rate
IND (Industrial): Data is streamed at the A/D update rate
FORMAT
DEFLT 7
DEFLT 8
CUSTOM
BUS FMT
Specifies whether the serial port sends data using the default stream format (using either 7 or 8
weight digits), a custom stream format (configured in STRMFMT; see Figure 3-10 on page 34), or
is streamed to a network bus (Profibus, Remote I/O, DeviceNet). For more specific information
on CUSTOM stream format, see Table 12-5 on page 77. BUS FMT is only used with serial bus
options.
Level 3 Submenus
Printer Port
BAUD
9600
19200
300
600
1200
2400
4800
Baud rate. Selects the transmission speed for the printer port.
BITS
8NONE
7EVEN
7ODD
Selects number of data bits and parity of data transmitted from the printer port.
TERMIN
CR/LF
CR
Termination character. Selects termination character for data sent from the printer port.
ECHO
ON
OFF
Allows the Print Echo to be turned on or off.
EOLDLY
0000000
0-255
End-of-line delay. Sets the delay period, in 0.1-second intervals, from when a formatted line is
terminated to the beginning of the next formatted serial output. Value specified must be in the
range 0-255, in tenths of a second (10 = 1 second).
SERIAL Menu
Parameter
Choices
Description
Table 3-5. Serial Menu Parameters (Continued)