Menu functions, Basic p3 menu – Elecraft P3 High-Performance Panadapter Manual User Manual
Page 33
33
Menu Functions
Tap
M E N U
and then turn the
SELECT
knob to scroll through the following list of menu functions. Tap the
SELECT
knob to select the displayed function.
Basic P3 Menu
Entry Default
Description
CenterEn
OFF
When OFF, the CENTER key does not adjust the center frequency when in
tracking mode.
Cursors
Bar
Bar produces a full height translucent bar on the spectrum display. “U” produces a
U-shaped cursor at the bottom of the spectrum display.
DispTest
off
Shows a test pattern with a color bar and the complete character set of each font.
Tap
M E N U
to exit.
FixMode
Half
Select what happens when the K3 VFO A is tuned off-screen in fixed-tune mode.
"Full" or "Half" means automatically adjust the center frequency by one full screen
or one half screen to keep VFO A within range. "Slide" means move the center
frequency the minimum amount. "Static" means don't move the center frequency at
all, that is, allow the cursor to move off screen.
FixTrack
Tracking
mode
Toggle between fixed-tune mode and tracking mode.
Font
9 x 14
Changes the font size.
FN Erase
N/A
Resets a function key to its un-programmed state. Tap or hold the function key to
be erased while this menu item is displayed.
Freeze
off
Freezes or un-freezes the current spectrum and waterfall display. This function is
most useful when assigned to a function key, which toggles between the frozen and
un-frozen state.
FW Rev
N/A
Displays the main firmware version number. It is not necessary to tap the
SELECT
knob for this function.
Knob Tap
N/A
When assigned to a function key, duplicates the
SELECT
knob’s tap function.
Knob Hold
N/A
When assigned to a function key, duplicates the
SELECT
knob’s hold function.
LCD Brt
100
Adjusts the display brightness from 0-100.
LCD Test
off
Set all display pixels to white at full brightness.
Lvl Cal
-5.8
Calibrates the “transfer gain” (gain from antenna to IF OUT connector) of the
transceiver (see page 31).
Lvl Lines
Dotted
Select the amplitude level graticule line type, dotted or solid.
Lvl Mode
dBm
Select the amplitude level display units, either dBm or S-units plus dB over S9.
MKRA
zero
N/A
Resets marker A to the center of the screen.
MKRB
zero
N/A
Resets market B to the center of the screen.