I/o data path protection – Dell PowerVault MD3220 User Manual
Page 92
92
Configuration: About Your Host
3 If the host context agent is running, click Action Stop, then wait
approximately 5 seconds.
4 Click Action Start.
I/O Data Path Protection
You can have multiple host-to-array connections for a host. Ensure that you
select all the connections to the array when configuring host access to the
storage array.
NOTE:
See the Deployment Guide for more information on cabling configurations.
NOTE:
For maximum redundancy, you must select all host connections to the array
when manually defining host topology. For example, a host may have two host
connections listed when manually configuring host access. For this host, you would
select the two host connections listed in the Available hosts section and add them
to the Selected hosts section using the Add button.
NOTE:
For more information on configuring hosts see "Configuration: About Your
If a component such as a RAID controller module or a cable fails, or an error
occurs on the data path to the preferred RAID controller module, the virtual
disk ownership is moved to the alternate non preferred RAID controller
module for processing. This feature is called failover.
Drivers for multi-path frameworks such as Microsoft Multi-Path IO (MPIO)
and Linux Device Mapper (DM) are installed on host systems that access the
storage array and provide I/O path failover.
For more information on Linux DM please see "Configuration: Device
Mapper Multipath for Linux" on page 179. For more information on MPIO
please see microsoft.com.
NOTE:
You must have the multi-path driver installed on the hosts at all times, even
in a configuration where there is only one path to the storage system, such as a
single port cluster configuration.
During a failover, the virtual disk transfer is logged as a critical event, and an
alert notification is sent automatically if you have configured alert
destinations for the storage array.
book.book Page 92 Tuesday, June 18, 2013 2:53 PM