Installing the Backplane

1 Align the holes on the backplane with the holes on the array.
2 Tighten the captive screw to secure the backplane to the chassis.

See Figure 15-16 for PowerVault MD3200 or Figure 15-17 for

PowerVault MD3220.

3 Replace the screws that secure the backplane to the chassis.

See Figure 15-16 for PowerVault MD3200 or Figure 15-17 for

PowerVault MD3220.

4 Align the slots on the RAID controller module/power supply cage with the

tabs on the chassis. See Figure 15-15.

5 Push the RAID controller module/power supply cage toward the front of

the array.

6 Replace the screws that secure the RAID controller module/power supply

cage to the chassis.

7 Replace the control panel. See "Installing the Control Panel" on page 220.
8 Replace the power supply/cooling fan modules. See "Installing a Power

Supply/Cooling Fan Module" on page 217.

9 Replace the hard drives. See "Installing a Hard Drive" on page 206.

10 Connect all the cables to the array.
11 Turn on the array and the host server.