beautypg.com

5 "enter wash" signal does not work, 6 "reenter code" signal does not work, 7 bill, coin or audit inputs do not work – Unitec POS4000 User Manual

Page 76: 8 main console keys do not work, 9 system resets each time power is turned on, Enter wash" signal does not work, Reenter code" signal does not work, Bill, coin or audit inputs do not work, Main console keys do not work, System resets each time power is turned on

background image

P O S 4 0 0 0

Document Number:

POS4010

56

Document Title:

Remote Code POS4000 Installation and Operations Manual

8.5 "Enter Wash" Signal Does Not Work

The "Enter Wash" feature produces a relay contact closure when any wash program is activated
(either by a valid customer code or cash). This relay stays on until the wash "In-Use" signal turns
on for that customer. In many circumstances, the "Enter Wash" signal for customer lights is
generated by the car wash equipment. If the carwash equipment generates the "Enter Wash"
control signal, check the carwash equipment.

If the interface board "Enter Wash" signal is used, perform the "Enter Wash" relay test described
in the Interface Test section. If the relay fails, replace the interface board.

Note:

The Enter Wash and Code Accepted/Wait relays are intended to control customer
guidance lights. The status of the relays can be determined by the LEDs that are
located on the board.

8.6 "Reenter Code" Signal Does Not Work

The "Reenter Code" signal should be activated for several seconds every time an incorrect code
is entered at the car wash entrance. If this does not occur, use the "Reenter Code" relay test
described in the Interface Test section. If this relay test fails, replace the interface board.

8.7 Bill, Coin or Audit Inputs Do Not Work

Audit counters are configured for either 24V AC/DC or 120V AC. To determine the voltage input
setting, refer to the "POS4000 Interface Board Wiring Diagram" in the back of this manual. The
input voltage jumper determines the acceptable input voltage range. The board will not work if
the wrong voltage is applied and the board WILL BE DAMAGED if 120V is applied to an input
jumpered for 24V board. To test the audit inputs, put the interface board in the test mode and
perform the audit input test as described in Section Error! Reference source not found.. If the
audit test fails, replace the interface board.

8.8 Main Console Keys Do Not Work

If the console keys do not function properly, remove power from the main console for a short
period. After power is returned to the main console, check key functions again. If one or two keys
still do not function (no beep when pressed), replace membrane keypad or keyboard PC board.
If a row or column of keys fails to function (no beep when pressed), check the keypad ribbon
connection between the keypad PC board and main PC board inside the console (25 wire ribbon
cable). If the ribbon connections and cable are OK, it is likely a main PC board failure. Replace
main PC board in main console.

8.9 System Resets Each Time Power Is Turned On

The lithium battery used to maintain the console memory when the console is off probably needs
replacement. Under normal usage this battery should last more than 5 years. Replace the main
PC board battery backup RAM socket in the main console.