beautypg.com

3 programming the output relays, Programming the output relays, Table 4. output relays – Unitec POS4000 User Manual

Page 73

background image

P O S 4 0 0 0

Document Number:

POS4010

53

Document Title:

Remote Code POS4000 Installation and Operations Manual

7.3 Programming the Output Relays

It is possible for each of the 5 backup customer codes to activate a different relay (or set of
relays). After the change-relays password has been entered, the interface will beep once and
wait for you to define which relay(s) should be activated when the first backup customer code is
entered (see table on the next page). After you press the keys that define which relays will
activate (press only one key at a time), press the 0 key to finalize your selections. The interface
board will beep twice to indicate that it is waiting for you to define the relays associated with the
second backup customer code. Repeat the process for all 5 backup customer codes.

Table 4. Output Relays

Key

Output Relay

1 1

2 2

3 3

4 4

5 5

6 6

7

1 pulse on Relay 1

8

2 pulses on Relay 1

9

3 pulses on Relay 1

Example to define relays as follows:

Code

#

Relays

1

1

2

1 + 4

3

2

4

2 + 4 + 5

5

2 pulses on 1 + 3

[4][3][5][3][9][2][1][0] (Change-relays password)
[1][0]

(Relay definition for code # 1)

[1][4][0]

(Relay definition for code # 2)

[2][0]

(Relay definition for code # 3)

[2][4][5][0]

(Relay definition for code # 4)

[8][3][0]

(Relay definition for code # 5)

The default output relay programming is as follows:

Customer Code

Output Relays Activated

1

1

2

2

3

3

4

4

5

5